搜索结果: 1-7 共查到“医学 Self-ligating”相关记录7条 . 查询时间(0.114 秒)
Frictional Resistance in Self-Ligating Orthodontic Brackets and Conventionally Ligated Brackets
Friction Self-ligation Brackets Systematic review In vitro
2010/3/5
Objective: To compare the amount of expressed frictional resistance between orthodontic self-ligating brackets and conventionally ligated brackets in vitro as reported in the literature.
Methods: S...
Third-Order Torque and Self-Ligating Orthodontic Bracket–Type Effects on Sliding Friction
Self-ligation Torque Friction
2010/3/5
Objective: To examine the influence of third-order torque on kinetic friction in sliding mechanics involving active and passive self-ligating brackets.
Materials and Methods: Wire-slot frictional f...
Pain Experience during Initial Alignment with a Self-Ligating and a Conventional Fixed Orthodontic Appliance System
Pain Orthodontic Self-ligating Appliance
2010/3/5
Objectives: To test the hypotheses that (1) there is no difference in the pain experience during the week following initial placement of two orthodontic appliances (SmartClip™ and Victory™...
Evaluation of the Frictional Resistance of Conventional and Self-ligating Bracket Designs Using Standardized Archwires and Dental Typodonts
Frictional resistance Conventional brackets Self-ligating brackets Typodonts Archwires
2008/12/11
The frictional behavior of four conventional and four self-ligating brackets were simulated using a mechanical testing machine. Analyses of the two-bracket types were completed by drawing samples of...
Friction of Conventional and Self-Ligating Brackets Using a 10 Bracket Model
Frictional resistance Conventional brackets Self-ligating brackets Archwires
2008/12/4
The friction generated by various bracket-archwire combinations previously has been studied using in vitro testing models that included only one or three brackets. This study was performed using a...
Frictional Evaluations of Dental Typodont Models Using Four Self-ligating Designs and a Conventional Design
Frictional resistance Self-ligating brackets Conventional brackets Typodont models Multiple brackets
2008/11/26
After a previous study using typodonts and three standardized archwire (AW) sizes, the frictional evaluations of four self-ligating brackets were directed toward the optimal AW-bracket system. Fou...
Failure Rate of Self-ligating and Edgewise Brackets Bonded with Conventional Acid Etching and a Self-etching Primer:A Prospective In Vivo Study
Self-ligating Self-etching primer Failure rate
2008/11/14
The purpose of this study was to comparatively assess the failure rate of self-ligating and edgewise brackets bonded with a self-etching adhesive and conventional phosphoric acid in patients followe...