搜索结果: 1-15 共查到“医学 impedance”相关记录27条 . 查询时间(0.061 秒)
Bioelectrical impedance: effect of 3 identical meals on diurnal impedance variation and calculation of body composition
diurnal variation body composition meal ingestion
2016/6/14
Bioelectrical impedance analysis (BIA) can be
used for estimating body composition. Earlier studies showed
that the ingestion of meals lowers bioelectrical impedance, but
none studied the effect of...
Bioelectrical impedance analysis in HIV-infected patients treated with triple antiretroviral treatment
AIDS anti-HIV agents body weight
2016/6/1
Triple antiretroviral treatment including protease
inhibitors (PIs) delays the clinical progression of HIV infection
and may thus reduce the risk of malnutrition. However, fat redistribution
(lipod...
Measurement of body water by multifrequency bioelectrical impedance spectroscopy in a multiethnic pediatric population
Total body water extracellular water intracellular water
2016/6/1
Bioelectrical impedance spectroscopy (BIS) may
provide a noninvasive, rapid method for the assessment of total
body water (TBW), extracellular water (ECW), and intracellular
water (ICW). Few studie...
Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults
Adiposity body fat body density humans
2016/5/31
Over the past decade, considerable attention has
been paid to accurately measuring body composition in diverse
populations. Recently, the use of air-displacement plethysmography
(AP) was proposed a...
Use of the leg-to-leg bioelectrical impedance method in assessing body-composition change in obese women
obesity fat-free mass percentage body fat
2016/5/30
There is little information on whether bioelectrical
impedance analysis (BIA) accurately predicts changes in body
composition associated with energy restriction, exercise, or both.
Bioelectrical impedance plethysmographic analysis of body composition in critically injured and healthy subjects
Bioelectrical impedance body composition critical illness
2016/5/30
Determination of body composition during critical
illness is complex because of various patient-related and
technical factors. Bioelectrical impedance is a promising
technique for the analysis of b...
Impact of a Right Ventricular Impedance Sensor on the Cardiovascular Responses to Exercise in Pacemaker Dependent Patients
cardiac pacing exercise responses chronotropic reserve index
2015/7/31
Background. The evaluation of the heart rate (HR) response to exercise is important for the assessment of the rate response algorithm of sensor-controlled pacemakers. This study examined the effects o...
Analysis of the Bioelectric Impedance of the Tissue-Electrode Interface Using a Novel Full-Spectrum Approach
electrode impedance
2015/1/12
Non-invasive surface recording of bioelectric potentials continues to be an essential tool in a variety of research and medical diagnostic procedures. However, the integrity of these recordings, and h...
Electromagnetic Impedance Tomography (EMIT): A New Method for Impedance Imaging
Condition number electromagnetic impedance
2010/1/6
We propose a new impedance imaging method,
electromagnetic impedance tomography (EMIT), in which the
boundary electric potential measurements in electrical impedance
tomography (EIT) are augmented ...
The Factorization Method for Electrical Impedance Tomography Data from a New Planar Device
The Factorization Method Electrical Impedance Tomography
2009/9/7
We present numerical results for two reconstruction methods for a new planar electrical impedance tomography device. This prototype allows noninvasive medical imaging techniques if only one side of a ...
Frequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications
Frequency-Division Multiplexing Electrical Impedance Tomography Biomedical Applications
2009/9/7
Electrical impedance tomography (EIT) produces an image of the electrical impedance distribution of tissues in the body, using electrodes that are placed on the periphery of the imaged area. These ele...
Cardiac output by impedance cardiography during head-out water immersion
human immersion cardiac
2009/7/14
This study was undertaken to ascertain the suitability of impedance cardiography for qualifying cardiac output during water immersion where the electrodes were wet. The cardiac output was compared dur...
Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure
the electrical impedance the pregnant human cervix-the effect probe size applied pressure
2010/2/25
Measuring cervical resistivity by a single observer with both the 3 and 12 mm probes is highly repeatable whilst inter-observer reproducibility is poor with the 3 mm probe but moderately good when the...
Estimating Arterial Wall Impedance Using a Strain-gauge Plethysmogram
Vascular function Arterial wall Plethysmogram Mechanical impedance
2009/6/5
This paper proposes a method that evaluates the beat-to-beat vascular conditions without needing to confine the forearm of the patient. It can estimate the mechanical impedance of an arterial wall by ...
An Optimal Spot-Electrodes Array for Voltage Pick-Up Determined from the Measurement of Transthoracic Electrical Impedance Change Following Cardiac Ejection
impedance or admittance cardiography cardiac output stroke volume optimal spot-electrodes array
2009/6/2
Electrical impedance (or admittance) cardiography is a simple and still potential method for non-invasive and continuous monitoring of stroke volume and cardiac output (CO) by detecting the electrical...