搜索结果: 1-11 共查到“生物医学工程 Reduction”相关记录11条 . 查询时间(0.203 秒)
Reduction Mammaplasty as a Treatment Option for Early Breast Cancer
Breast Reduction Cancer Bilateral Mammaplasty Conservative
2013/1/30
Background: Although reduction mammaplasty is a well-known technique for cosmetic purposes, there are few previous reports regarding its application and clinical outcome following conservative breast ...
Reduction of CPR artifacts in the ventricular fibrillation ECG by coherent line removal
CPR artifacts the ventricular fibrillation ECG coherent line removal
2010/2/25
The localized coherent line removal algorithm reduces CPR-artifacts in VF-ECG, but does not eliminate them. Our SNR-improvements are in the same range as offered by multichannel methods of Rheinberger...
Kinetic mechanism reduction based on an integer programming approach
Kinetic mechanism reduction an integer programming approach
2009/12/24
Kinetic mechanism reduction based on an integer programming approach.
Deformation-based nonlinear dimension reduction: applications to nuclear morphometry
nonlinear dimension dimension reduction nuclear shape analysis
2009/12/23
Deformation-based nonlinear dimension reduction: applications to nuclear morphometry.
Feature reduction for improved recognition of subcellular location patterns in fluorescence microscope images
proteomics subcellular location pattern subcellular location features
2009/12/23
The central goal of proteomics is to clarify the mechanism by which each protein in a given cell type carries out itsfunction. Automated protein subcellular location determination by fluorescence micr...
Partial Volume Reduction by Interpolation with Reverse Diffusion
Partial Volume Reduction Interpolation
2009/9/8
Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the midst of a voxel giving a signal value that is a mixture of the two. We propo...
Experimental Investigation of Angular Stackgram Filtering for Noise Reduction of SPECT Projection Data: Study with Linear and Nonlinear Filters
SPECT Projection Data Nonlinear Filters
2009/9/7
We discuss data filtering prior to image reconstruction. For this kind of filtering, the radial direction of the sinogram is routinely employed. Recently, we have introduced an alternative approach to...
Improvement of Computer-aided Diagnosis Scheme for Detection of Clustered Microcalcifications in Mammograms:Reduction of False Positives Based on Filter Bank
mammogram microcalcification computer-aided diagnosis (CAD) filter bank, wavelet
2009/6/9
We have developed a computer-aided diagnosis scheme for the detection of clustered microcalcifications in mammograms. Using a filter bank, the mammogram image is first decomposed into eight sub-images...
Reduction of muscle fatigue by catchlike-inducing intermittent electrical stimulation in rat skeletal muscle
muscle fatigue catchlike-inducing intermittent electrical stimulation rat skeletal muscle
2009/3/2
Catchlike property is the force enhancement produced when a brief, high-frequency burst of pulses is added to a constant low-frequency stimulation. In functional electrical stimulation, constant low...
Analysis and interpretation of dynamic FDG PET oncological studies using data reduction techniques
dynamic FDG PET oncological studies data reduction techniques
2010/2/25
We have applied principal component analysis to provide high-contrast parametric image sets of lower dimensions than the original data set separating structures based on their kinetic characteristics....
APPLICATION OF E-COMMERCE IN LOCAL HOME SHOPPING AND ITS CONSEQUENCES ON ENERGY CONSUMPTION AND AIR POLLUTION REDUCTION
E-COMMERCE LOCAL HOME SHOPPING ENERGY CONSUMPTION AIR POLLUTION REDUCTION
2010/2/1
Methyl Tert-Butyl Ether (MTBE) is one of the ether oxygenates which its use has been increased within the last twenty years. This compound is produced from isobutylene and methanol reaction that is us...