搜索结果: 1-4 共查到“环境医学 Systems”相关记录4条 . 查询时间(0.234 秒)
THE COLONIZATION OF HOT WATER SYSTEMS BY LEGIONELLA
Legionella pneumophila hot water system temperature effects legislation
2010/12/22
This study surveyed Legionella in 805 samples taken from 18 hot water systems under operating conditions. The results were analyzed and discussed in relation to water temperature.
MONITORING LEGIONELLA SPECIES IN HOSPITAL WATER SYSTEMS.LINK WITH DISEASE AND EVALUATION OF DIFFERENT DETECTION METHODS
Legionella hospital potable water system Standard PN-ISO11731-2
2010/12/23
The aim of this work was to evaluate three currently available isolation methods for Legionella using water samples and swabs of a single pediatric hospital water system. Additionally, high risk patie...
GRAM-NEGATIVE BACTERIA IN WATER DISTRIBUTION SYSTEMS OF HOSPITALS
Gram-negative bacteria Legionella Non-Enterobacteriaceae
2010/12/23
A total of 67 samples of tap water were collected from faucets and showerheads in 6 hospitals located in the Lublin province (eastern Poland). The samples were examined for the presence and species co...
DESIGN COMPARISON OF EXPERIMENTAL STORM WATER DETENTION SYSTEMS TREATING CONCENTRATED ROAD RUNOFF
Environment hydrology water resources infrastructure planning storm water
2010/2/5
Urban drainage systems are vital infrastructure assets, which protect our cities from flooding and transmission of waterborne diseases. The objective of this research was to assess the treatment effic...