搜索结果: 1-15 共查到“生物医学工程 Ultrasound”相关记录37条 . 查询时间(0.098 秒)
The High Frequency (HF) Ultrasound as a Useful Imaging Technique for the Efficacy Assessment of Different Anti-Cellulite Treatments
Aesthetic Medicine Cellulite Anti-Cellulite Treatment High Frequency Ultrasound Skin Ultrasound
2013/1/29
The purpose of the research was to evaluate the role of high frequency ultrasound in monitoring and efficacy assessment of anti-cellulite treatments. A group of 66 women used 3 different types of anti...
Ultrasound-Guided Peri-Lymphatic and Peri-Neural Corticosteroid Injection as an Adjuvant to Pain and Lymphedema Management in Terminal Cancer: Two Case Reports
Corticosteroids Adjuvant Cancer Pain Lymphedema Peripheral Nerve Block
2013/1/30
We are reporting two patients presented with intractable cancer pain that was treated with a novel application of an ultrasound-guided peripheral nerve block using corticosteroid. This technique offer...
On the relationship between encapsulated ultrasound contrast agent and pressure
relationship encapsulated ultrasound contrast agent pressure
2010/1/6
Noninvasive measurement of pressure within the heart cavities and other internal organs
(e.g., kidney, liver) has significant clinical value but currently is not feasible. Noninvasive
pressure estim...
Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation
Ultrasonic imaging Coded excitation Pulse compression
2010/1/6
A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizesthe signal-to-noise ratio (SNR) and minimizes sidelobes at the output of th...
Phase Unwrapping for 2-D Blind Deconvolution of Ultrasound Images
Phase unwrapping Poisson equation multiresolution
2010/1/6
In most approaches to the problem of two-dimensional
homomorphic deconvolution of ultrasound images, the estimation
of a corresponding point-spread function (PSF) is necessarily
the first stage in ...
A new method of ultrasound color flow mapping
Doppler processing Autocorrelation Ultrasound simulation
2010/1/6
Conventional ultrasound color flow mapping systems estimate and visualize only the axial velocity component. To obtain thetransverse velocity component a modification of a multiple-beam method is prop...
A High-Resolution Technique for Ultrasound Harmonic Imaging Using Sparse Representations in Gabor Frames
Gabor frames harmonic imaging sparse representations
2010/1/6
Over the last few decades there were dramatic
improvements in ultrasound imaging quality with the utilization
of harmonic frequencies induced by both tissue and echo-contrast
agents. The advantages...
Robust Estimation of Ultrasound Pulses Using Outlier-Resistant De-Noising
Outlier-resistant estimation ultrasound pulse estimation
2010/1/6
A different approach to the problem of estimation of
the ultrasound pulse spectrum, which usually arises as a part of
ultrasound image restoration algorithms, is presented. It is shown
that this es...
Shift-Invariant , DWT-Based “Project ion” Method for Estimation of Ultrasound Pulse Power Spectrum
Shift-Invariant DWT-Based Ultrasound
2010/1/6
An approach to computing estimates of the
ultrasound pulse spectrum from echo-ultrasound RF sequences,
measured from biological tissues, is proposed. It
is computed by a “projection” algorithm base...
Blind Deconvolution of Ultrasound Sequences Using Nonparametric Local Polynomial Estimates of the Pulse
Blind deconvolution pulse estimation ultrasound
2010/1/6
The problem of reconstructing the reflectivity of a
biological tissue is examined by means of blind deconvolution of
the echo ultrasound signals. It is shown that the quality of the
reconstruction ...
Calibration Method for Determining the Physical Location of the Ultrasound Image Plane
Calibration Method Determining the Ultrasound Image Plane
2009/12/22
This paper describes a calibration method for determining the physical location of the ultrasound (US) image plane relative to a rigidly attached 3D position sensor. A calibrated US probe can measure ...
Model-Based Reconstructive Elasticity Imaging Using Ultrasound
Model-Based Reconstructive Elasticity Imaging
2009/9/7
Elasticity imaging is a reconstructive imaging technique where tissue motion in response to mechanical excitation is measured using modern imaging systems, and the estimated displacements are then use...
MMSE Reconstruction for 3D Freehand Ultrasound Imaging
MMSE Reconstruction 3D Freehand Ultrasound Imaging
2009/9/4
The reconstruction of 3D ultrasound (US) images from mechanically registered, but otherwise irregularly positioned, B-scan slices is of great interest in image guided therapy procedures. Conventional ...
Development of a New Method for Discriminating Embolus from Air Bubble by Active Ultrasound Doppler Method. 1 (Experiments of Ultrasound Irradiation Perpendicular to a Tube Axis in Flows of Water and Modeled Blood)
USD TCD cerebral embolism characteristic acoustic impedance acoustic radiation force
2009/8/24
An “active” ultrasound Doppler method was newly developed in order to directly and easily discriminate emboli from micro bubbles flowing in blood vessel. The principle of this method is based on measu...
Implications of 2D Ultrasound Findings of the Scrotum in Asymptomatic Microfilaria Carriers of Wuchereria bancrofti Infection
Night blood survey W.bancrofti filariasis hydrocele
2010/12/10
The incubation period of lymphatic filarial disease is long, and a large proportion of individuals infected with W. bancrofti are asymptomatic. In India, the most common presenting clinical manifestat...